CHINT DZ47LE-32 C10 10A RCBO Circuit Breaker – 230V, 30mA

$18.00
In stock: 5 available
Product Details

LASER PARTS | ELECTRICAL COMPONENTS & CIRCUIT PROTECTION

CHINT DZ47LE-32 C10 10A RCBO Circuit Breaker – 230V, 30mA

The CHINT DZ47LE-32 C10 circuit breaker is a residual-current circuit breaker with overcurrent protection (RCBO) designed for compatible electrical systems operating at 230V AC. It combines overload, short-circuit, and electrical-leakage protection in one compact device.

Rated at 10 amps with a Type C trip curve, this breaker is designed to respond to excessive circuit current while accommodating brief startup current in appropriately rated equipment.

Its 30mA residual-current sensitivity provides additional protection by detecting current imbalance between the line and neutral conductors. When a qualifying fault occurs, the breaker is designed to disconnect the circuit.

The unit features a blue ON/OFF operating lever, an orange leakage-test button, line-and-neutral connections, and a DIN-rail mounting design for installation in compatible electrical enclosures.

Important: This breaker must match the electrical requirements of the equipment and the original protective device. A matching 10A rating alone does not guarantee compatibility.

Key Features

  • Combined Circuit Protection: Provides overload, short-circuit, and residual-current protection in one device.
  • 10A Rated Current: Designed for compatible electrical circuits requiring a 10-amp breaker.
  • 230V AC Operation: Intended for appropriately rated single-phase electrical systems.
  • Type C Trip Curve: Accommodates brief startup current while providing overcurrent protection.
  • 30mA Leakage Sensitivity: Detects qualifying electrical current imbalance and initiates disconnection.
  • 6kA Breaking Capacity: Marked for a 6,000-amp short-circuit breaking capacity under its specified operating conditions.
  • Built-In Test Button: Orange test button for checking the residual-current trip function.
  • Manual Operating Lever: Blue ON/OFF lever for manual operation and resetting after a fault has been corrected.
  • Line and Neutral Connections: Designed for a compatible single-phase line-and-neutral circuit.
  • DIN-Rail Mounting: Suitable for installation in compatible electrical cabinets and distribution enclosures.

Product Specifications

Manufacturer CHINT
Model DZ47LE-32
Breaker Marking C10
Product Type Residual-Current Circuit Breaker with Overcurrent Protection (RCBO)
Rated Current 10A
Rated Voltage 230V AC
Trip Curve Type C
Rated Residual Operating Current 30mA (0.03A)
Marked Residual Trip Time 0.1 Second or Less
Short-Circuit Breaking Capacity 6,000A (6kA)
Pole Configuration 1P+N (Line and Neutral)
Protection Functions Overload, Short Circuit, Residual Current
Test Button Integrated Orange T Button
Operating Lever Manual ON/OFF
Mounting Style 35mm DIN Rail
Connection Type Screw Terminals
Standard Marked on Unit IEC 61009-1
Quantity Included 1 Circuit Breaker
Rabbit Laser USA SKU 338

Understanding RCBO Protection

An RCBO combines the functions of a traditional circuit breaker and a residual-current protective device.

Overload Protection: When connected equipment draws excessive current for a sufficient period, the breaker is designed to disconnect the circuit to help prevent overheating and electrical damage.

Short-Circuit Protection: When a qualifying short circuit causes a sudden increase in current, the breaker responds to interrupt the fault within its rated breaking capacity.

Residual-Current Protection: The breaker monitors the difference between current flowing through the line and neutral conductors. A qualifying imbalance can indicate electrical leakage and cause the breaker to trip.

The 30mA sensitivity offers an additional layer of protection against certain electrical faults. However, it does not eliminate all electrical-shock risks or replace proper grounding, wiring, and other required safety measures.

Built-In Test Button

The orange T button is designed to test the breaker's residual-current trip mechanism under the conditions specified by the manufacturer.

When the breaker is correctly installed and supplied with the required electrical power, operating the test button should cause the device to trip.

The residual-current protection should be tested according to the manufacturer's maintenance instructions.

Important: If the device fails a prescribed test, do not rely on it for electrical protection. Have the circuit and breaker inspected by a qualified electrician.

Compatibility

This breaker is intended for compatible laser machines and electrical systems requiring a DZ47LE-32 C10, 230V AC, 10A, 30mA RCBO with the appropriate circuit configuration and breaking capacity.

Before ordering, compare the replacement breaker with your original component:

  • Manufacturer and model number
  • 10A rated current and Type C trip curve
  • 230V AC voltage rating
  • 30mA residual-current sensitivity and applicable detection type
  • 6kA short-circuit breaking capacity
  • Line-and-neutral terminal configuration
  • Physical dimensions and DIN-rail mounting requirements
  • Wiring diagram and installation requirements
  • Applicable electrical codes and equipment requirements

Important: Breakers with similar housings or identical C10 markings may have different leakage ratings, trip characteristics, terminal arrangements, or protective capabilities.

Do not substitute a breaker with a higher amperage rating or different protective characteristics without approval from a qualified electrical professional.

Installation & Safety

  • Installation and replacement should be performed by a qualified electrician familiar with the equipment and applicable electrical requirements.
  • Disconnect and isolate the electrical supply before accessing the machine's electrical cabinet.
  • Verify that all affected circuits are de-energized using appropriate testing equipment.
  • Confirm that the replacement breaker matches the original circuit protection requirements.
  • Mount the breaker securely on a compatible DIN rail.
  • Connect the line, neutral, and load conductors according to the diagram and terminal markings on the device.
  • Use properly sized conductors and the manufacturer's specified terminal tightening torque.
  • After installation, perform all required electrical and protective-function tests before returning the equipment to service.

Safety Note: If the breaker trips repeatedly, do not continue resetting it without investigating the cause. Repeated tripping may indicate damaged wiring, excessive load, current leakage, or a failing electrical component.

The breaker must not be bypassed or modified to prevent tripping. Electrical protection components are essential to safe machine operation.

Need Help Finding the Right Circuit Breaker?

Rabbit Laser USA supplies replacement circuit breakers and electrical components for CO2 laser engraving and cutting machines. If you're unsure whether this DZ47LE-32 C10 breaker matches your equipment, contact our technical support team with your machine model and clear photographs of the original breaker's markings and connections.